Soundlag acoustic pipe wrap
Soundguard logo
 

Uses in brief

Applying Soundlag to pipesAcoustic lagging of hydraulic pipework to muffle hydraulic noises to within the requirements of Rw45 of the Australian Building Code.

Overview

Soundlag 4525C is the most cost effective acoustic pipe lagging to satisfy the Australian Building Code's Rw45 requirement. Soundlag 4525C reduces the noise in hydraulic and waste pipes by 25 dB(A) and is the easiest installed of all the available systems.

Construction

Construction of SoundlagConstructed of hydrolysis-resistant foam and flexible loaded vinyl, Soundlag 4525C is protected by a tough reinforced foil to last a lifetime.

Performance

The Australian Building Code requires Rw ratings of 30 and 45 in non- habitable and habitable rooms respectively.

Pipes correctly lagged with Soundlag 4525C within the right structure achieve these results. The diagrams outlined above are systems provided by PKA Acoustic Consultants, based on the actual test results (ATF 750B Report) carried out at the National Acoustic Laboratory, Sydney, Australia.

The final results can be influenced adversely by air-conditioning ducts, lack of air gap, openings in ceilings such as vents, downlights, manholes and exhaust fans.

Graph of insertion loss of Soundlag

Sound Insertion Loss (A-weighted) Sound Power Levels, National Acoustic Laboratory (NAL) test, Report Reference ATF 750B, ATF 750F, ATF 749K

Specifications

Product Code: 17054073
Standard roll size: 1.35 m x 5.0 m
Insertion loss (NAL ATF 750B report): 25dB(A) (1/3 octave band 100 Hz to 10 kHz)
Flammability (AS 1530.3, 1989): Ignitability Index = 0
Spread Of Flame Index = 0
Heat Evolved Index = 0
Smoke Developed Index = 0-1

Ask for any of the Soundguard technical data now. 

Disclaimer

No information or advice stated or implied herein constitutes an undertaking or guarantee of performance in respect of any service or product or capability. You must not act solely on the basis of the material presented, which could, despite due care, be in error or misleading. You are urged to seek the maker's formal advice before acting on any of the material on any page.  Any problems with this website, email soundguard@mentorr.com.au. 
 

 

 

Product selector for ...
Building & Architecture
Marine
Industrial & Manufacturing
Transport

Brands
Soundlag
Wavebar
Soundpad
Soundpaint
Soundsorber
Soundsorber Barrier
Silentstep
Sylomer
Deci range
Data sheets in ARABIC
Data sheets in ASIAN languages

Extras
News and features
About Soundguard
Glossary
Site map
Contacts

 
Ask for advice and tech data